![Baso Gas Products C670AGA-1C Intermittent Pilot Ignition Control Module — New England Supply House spec card [NESH-SPEC-CARD-V2]](http://newenglandsupplyhouse.com/cdn/shop/files/spec-9032660910302.png?v=1782840105&width=1445)
The Baso Gas Products C670AGA-1C Intermittent Pilot Ignition Control Module is a microprocessor-based solution for reliable furnace and intermittent pilot boiler operation. It manages the ignition sequence with a single-trial approach and supports natural gas or liquid propane gas, delivering precise timing for safe, efficient starts.
Powered by 24 Volt AC and featuring remote flame sense, it delivers fast, dependable ignition and enhanced burner safety across a range of applications.
Designed for furnaces and intermittent pilot boilers, the unit tolerates temperatures from -40 to 176 degrees F and fits compactly in tight control spaces. Its rugged build and CSA (AGA/CGA) approval ensure compliant, durable performance in professional installations.
Key specifications and dimensions include size 4.85 in L x 3.15 in W x 1.5 in H, ignition trial time 85 seconds, prepurge 15 seconds, inter-purge 15 seconds, and post-purge 0 seconds. It also supports single-trial ignition with rollout switch included for added safety.
- Microprocessor-based intermittent pilot ignition control
- Supports natural gas or propane gas fuels
- Remote flame sense with 24V AC supply
- 1-trial ignition sequence; 85-second ignition trial
- Prepurge 15 seconds; Inter-purge 15 seconds; Post-purge 0 seconds
- CSA (AGA/CGA) approved for safety and compliance
- Compact footprint: 4.85 in L x 3.15 in W x 1.5 in H
- Includes rollout switch for added safety
Specifications
| Type | Microprocessor Based, Intermittent Pilot |
|---|---|
| Size | 4.85 Inch Length x 3.15 Inch Width x 1.5 Inch Height |
| Temperature Rating | -40 to 176 Deg F |
| Power Rating | 24 Volt AC |
| Application | Furnace, Intermittent Pilot Boiler |
| Approvals | CSA (AGA/CGA) |
| Fuel Type | Natural/Liquid Propane Gas |
| Ignition Trial Time | 85 Second |
| Prepurge Time | 15 Second |
| Flame Sense Type | Remote |
| Ignition Sequence | 1-Trial |