![ICM Controls ICM2918 Intermittent Pilot Ignition — New England Supply House spec card [NESH-SPEC-CARD-V2]](http://newenglandsupplyhouse.com/cdn/shop/files/spec-9032831402206.png?v=1782844505&width=1445)
ICM Controls ICM2918 is a universal intermittent pilot ignition control that replaces OEM units in a wide range of heating systems, including residential furnaces and boilers. This compact module delivers reliable ignition timing and robust operation amid varying flame conditions.
As a dependable DSI module, the ICM2918 serves as an OEM replacement for the Honeywell S8610U and is compatible with Johnson Controls, Robertshaw, White-Rodgers, Fenwal, HSC, Camstat, and other major brands.
Engineered for durable performance, this ignition control offers precise ignition sequencing, reliable flame sensing, safe operation across temperature ranges, and compatibility with standard gas valve interfaces.
Ideal for service technicians and replacement parts, it delivers universal compatibility, easy wiring, minimal downtime, and seamless integration with existing controls.
- Universal compatibility across major brands (Johnson Controls, Robertshaw, White-Rodgers, Fenwal, Camstat, HSC)
- Replaces Honeywell S8610U DSI module
- Intermittent pilot ignition control for reliable startup
- OEM replacement with simple wiring and mounting
- Durable construction for long life and consistent performance
Specifications
| Control Voltage | 18-30 VAC, 50/60 Hz |
|---|---|
| Trial for Ignition | 15 or 90 seconds, switch settable |
| Pre-Purge | 0 or 30 seconds, switch settable |
| Application | Single or dual rod intermittent pilot |
| Fuel | Natural gas or LP |
| Operating Temperature | -40 F to 165 F |
| Dimensions | 5.50 in. x 4.00 in. x 2.00 in. |
Cross-Reference & Compatibility
ICM Controls ICM2918 Ignition Control Board is a direct replacement for S8610U.
| Replaces part numbers | S8610U |
|---|---|
| Alternate part numbers | ICM290A |
Universal replacement for over 280 intermittent pilot ignition models.