The Honeywell Home S8801A1110 from Resideo is an external direct spark ignition (DSI) control module for gas-fired furnaces, boilers and heating appliances. It is a low-voltage control that fires an external high-voltage spark generator to light the burner, with one trial for ignition, a 30-second pre-purge and a 4-second trial time. It uses a two-rod configuration and includes an alarm terminal. Flame failure response time is 0.8 second minimum to 1.3 seconds maximum at 5 uA, 60 Hz, and the control is listed to UL 60730-1 and UL 60730-2-5.
The S8801A1110 is a functional replacement for the S89F1098. Backed by a one-year manufacturer warranty.
Specifications
| Part Number | S8801A1110 |
|---|---|
| Application | Low voltage, direct spark ignition control module for gas-fired furnaces, boilers and heating appliances |
| Ignition Source | External High Voltage Spark Generator |
| Flame Failure Response Time | 0.8 sec min 1.3 sec maximum at 5uA/ 60Hz |
| Standards | UL 60730-1, UL 60730-2-5 |
| Configuration | Two rod, 1 trial for ignition, 30 sec pre-purge, 4 sec trial time, alarm terminal |
| Replaces | S89F1098 (functional replacement) |
| Warranty | 1 Year |